Skip to content
EASUN Isolar-SML-5kw parallel Guide

EASUN Isolar-SML-5kw parallel Guide

1.Connect the Inverter only with battery not connect with PV and load, press the switch on the side to on position ,waiting it running normally

2.Switch off-- press the switch to off position.

the LCD still can light 30 seconds

during the 30 seconds set 28 to PAL

3.for single phase the AC in of each inverter need conected,battery .for 3 phase each phase AC in connected togheter.

4.220V AC out, single phase , connect together.

3 phase each phase connected together.

5. for the PV in, PV for each inverter must individual, connect together will damage the inverter

Previous article What do I need to pay attention to install Easun power solar inverters?
Next article Help you find a easy way resolve the after-sales problem for EASUNPOWER solar inverter

Leave a comment

Comments must be approved before appearing

* Required fields